STED

Abberior Instruments easy3D STED: Explore the 3rd dimension

3d module rendered crop.1280x0

  • Spatial Light Modulator (SLM) technology
  • Resolution tunable between xy and z
  • Single STED beam
  • Enables the use of different objective lenses
  • Resolution typically 80 × 80 × 90 nm
  • Engineered for maximum stability

Abberior Instruments is proud to announce its new easy3D STED module which uses a completely novel approach to 3D STED microscopy. At its core, a programmable spatial light modulator (SLM) is used to create the phase patterns required for 2D and 3D STED microscopy. At the same time, it can also be used to correct for optical aberrations.

 

The SLM allows a revolutionary design with only one STED beam instead of two separate STED beams for lateral (xy) and axial (z) resolution enhancement, respectively. The resolution enhancement can be tuned between pure xy and mainly z enhancement. The single-beam design obsoletes any beam recombination and alignment resulting in unrivaled system stability.

 rtemagicc ai 3d png.1280x0         rtemagicc traditional 3d png.1280x0

Abberior Instruments easy3D STED Design                                                                 Conventional 3D STED Design

 objective lens comparison.1280x0

Freely Choose Your Objective Lens for 3D STED Imaging

Aberrations do matter! This measurement impressively demonstrates the effect of a refractive index mismatch. When an oil immersion lens is used to image a layer of fluorescent beads imaged through 13 ?m of water the image suffers from a significant loss in fluorescence intensity. This results in unusable images, both for confocal and for STED imaging (left).

In contrast, when a water immersion lens is used both layers of beads are imaged with the same quality (right). The Abberior Instruments easy3D design allows you to change the objective lens on the fly and to use the most suitable lens in STED mode also!

Key Benefits

  • Tune the resolution in xy and z to fit your imaging problem.
  • Use any combination of 2D or 3D STED phase plates or any user-defined phase modulation.
  • Aberration correction: keep the STED PSF in shape even deep inside your sample (>20 ?m)
  • Switch between objective lenses on the fly: oil immersion, water immersion, silicone oil immersion...
  • Resolution easy3D: 100 × 100 × 100 nm minimum, 80 × 80 × 90 × nm typical
  • Resolution 2D: better than 30 × 30 nm.
  • Any Abberior STED system can be upgraded with the easy3D STED module.

Download pdf Brochures:

download ai brochure folder.300x0                              download abberior instruments easy3d sted.300x0

 

Abberior Instruments Product Brochure        Abberior Instruments Easy3D STED

References

You are here: Home Superresolution Microscopy STED Abberior Instruments easy3D STED: Explore the 3rd dimension