Lasermet Laser Enclosures

Class 1 Enclosures for Class 4 Lasers - CE Certified to EN 60825-4

Laser safety cell 

 Class 1 laser cabin

 Class 1 laser safety enclosure

  Laser safety cell   

 Class 1 laser cabin                     

 Class 1 laser safety enclosure 


Lasermet supply and install Class 1 room size laser enclosures for high power lasers. All enclosures are sold tested and certified to EN 60825-4 (Safety of Laser Products Part 4 - Laser Guards). These can be supplied complete with interlock system and illuminated signs. Fume extraction and/or air conditioning can also be supplied, as can CCTV. This is a cost effective and extremely easy method of enclosing your laser system which fulfils your safety requirements and frees up space for other activities.
 

The specification of the enclosure to EN 60825-4 is as follows:

Irradiated Area
PEL (T2) 100 s
PEL (T3) 10 s
4 mm2
61 MW/m2 34 MW/m2
2000 mm2
2.7 MW/m2 1.5 MW/m2

Shown above are pictures of a 5 m x 5 m x 3 m enclosure with double door entrance, for a robot mounted 2 kW fibre laser. This enclosure was supplied complete with interlock system, laser safe vents, CCTV and lighting.

CE Certified Laser Blocking Partitions

We also supply CE certified laser blocking partitions with or without doors, for dividing one laser lab into two or more sections. These semi-permanent partitions are cost effective and extremely quick to install, without the mess and fuss of building a brick or plasterboard wall. As such they offer an alternative to traditional methods of room division, and can also be easily undone at a later date if required. Alternatively they can be left as a permanent installation.

All laser safety partitions are tested and certified to EN 60825-4 with the following specification:

Irradiated Area
PEL (T2) 100 s
PEL (T3) 10 s
4 mm2
61 MW/m2 34 MW/m2
2000 mm2
2.7 MW/m2 1.5 MW/m2